Oxidation Resistant Transformer Oil
Transformer oil is an important insulating and heatdissipating medium used in transformers for power transmission and transformation projects, playing a crucial role in ensuring the safe operation of substations. As such, transformer oil must meet essential functional requirements, including insulation and heat dissipation, along with high withstand voltage and low dielectric loss as fundamental electrical performance metrics. With advancements in highvoltage power transmission technology, transformer oils are required to possess high oxidation stability, thermal stability, and effective resistance to gas precipitation. Additionally, strict control over trace water and particulate impurities has become necessary.
Product Details:Oxidation Resistant Transformer Oil
During the charged operation of a transformer, two types of losses occur: "copper consumption" and "core loss." These losses manifest as heat. If the heat generated in the coils is not dissipated, it will accumulate, leading to an increase in temperature within the iron core. This accumulation can damage the solid insulation surrounding the coil, potentially resulting in coil burnout. However, when transformer oil is used, the heat generated inside the coil is first absorbed by the oil. The oil then circulates, effectively dissipating the heat and ensuring the safe operation of the equipment.
Parameter:
Sports Event | Quality Indicators | measured value | Test Methods |
Functional characteristics | |||
Pour Point/°C | -50 | -57.5 | ISO 3016 |
Kinematic viscosity (40℃)/(m㎡/s) | ≯12 | 9.52 | ISO 3104 |
Kinematic viscosity (-10°C)/(mm²/s) | ≯1800 | 1028 | ISO 3104 |
Water content/(mg/kg) | ≯30/40 | 9.0 | IEC 60814 |
Breakdown voltage/kV (untreated oil) | ≮30 | 64.5 | IEC 60156 |
Density (20°C)/(g/ml) | ≯895 | 886 | ISO 12185 |
Dielectric loss factor (90°C) | ≯0.005 | 0.0005 | IEC 60247 |
Refining/stabilizing properties | |||
exterior condition | Clear and transparent, free of sediment and suspension (of atmospheric pollution) | Clear and transparent, free of sediment and suspension (of atmospheric pollution) | visual assessment |
Acid value (mgKOH/g) | ≯0.01 | 0.0008 | IEC 62021- 1 |
Interfacial tension/(mN/m) | No general requirements | 45.3 | ISO 6295 |
Total sulfur content (mass fraction)/% | No general requirements | No general requirements | ISO 14596 |
corrosive sulfur | non-corrosive | non-corrosive | DIN 51353 |
Content of antioxidant additives (mass fraction)/percent Oil with antioxidant additives (U) | ≯0.08 | 0.065 | IEC 60666 |
2-Furfural content/(mg/kg) | ≯0.1 | 0.012 | IEC 61198 |
Operational characteristics | |||
Oxidation stability (120°C) Test time: 332h | - | - | - |
--Total acid value (in KOH)/(mg/g) | ≯1.2 | 0.04 | IEC 61125 Act C |
--Oil sludge (mass fraction)/% | ≯0.8 | 0.020 | IEC 61125 Act C |
--Dielectric loss factor (90°C) | ≯0.500 | 0.004 | IEC 60247 |
Gassing/(mm/min) | No general requirements | No general requirements | IEC 60628 |
Health Safety and Environmental Characteristics (HSE) | |||
Flash point (closed)/°C | ≮135 | 148.2 | ISO 2719 |
PCA content (mass fraction)/% | ≯3 | 0.8 | BS 2000 Part 346 |
Polychlorinated biphenyl (PCB) content/(mass fraction)(mg/kg) | undetectable | undetectable | IEC 61619 |
1. Applicable Industry
Drilling equipment: Transformer oil serves as a lubricant, minimizing friction and wear, while ensuring the stability of equipment in high-temperature conditions.
Oilfield Electrical Equipment: In electrical equipment used in oilfields, transformer oil provides essential insulation and cooling, ensuring dependable performance in challenging environments.
Electric Locomotives: Within the electrical systems of electric locomotives, transformer oil is utilized to offer insulation, facilitate the safe transmission of electric current, and assist in heat dissipation.
Signal Systems: Transformer oil is employed in railroad signaling equipment to provide insulation, enhancing both the efficiency and safety of the signaling system.
2. Oil Change Inspection
When assessing a transformer, it is important to take into account its operational history and maintenance records. Frequent failures or a decline in performance may indicate a need to evaluate the oil quality and possibly replace it. Additionally, considering the design life and age of the transformer is crucial. If the transformer is nearing or has surpassed its expected lifespan, changing the transformer oil might be necessary to maintain safe operations.
Own Factory
Haikun, with 5000 - ton basic oil storage capacity, guarantees continuous production.
Employees at Working
The staff at Haikun work happily in the industrial oil sector. They cooperate closely, promoting the company's development.
Canned Oil Products
With reliable packing procedures, Haikun Petrochemical packs transformer - related products in 200L iron drums and 20000L liquid bags, ensuring secure packing for sea - borne transport.
Transportation
Our firm, Haikun, has mastered sea - freight operations. We ship transformer - related products to Russia, South America, and numerous African countries.
Enterprise Culture
We strongly believe that only by continuously learning can we keep up with the times' rapid progress. Therefore, we inspire our employees to maintain a learning - oriented attitude, actively embrace new knowledge and skills, and continuously enhance their overall qualities, so as to fuel new growth momentum for the enterprise.
Customer Testimonials
Transformer oil from Haikun is excellent. They pay attention to every detail of customer needs. The product parameters match exactly, and the assay is real. The sales service was great. - Europe, Brown Emily