Silicone Based Dielectric Cooling Oil
As an insulating and heatdissipating medium, transformer oil is essential for the operation of transformers in power transmission and transformation projects, significantly contributing to the safety of substations. Therefore, the primary functional requirements for transformer oil are effective insulation and heat dissipation, with high withstand voltage and low dielectric loss being key electrical performance indicators. With the progression of highvoltage power transmission technology, transformer oils must demonstrate superior oxidation stability, thermal stability, and resistance to gas precipitation to ensure compatibility with highvoltage conditions. Moreover, controlling trace water and particulate impurities has become increasingly stringent.
Product Details:Low Viscosity Insulation Fluid for HV Transformers
Transformer in the process of charged operation, will produce “copper consumption” and “core loss”. These two parts of the loss are in the form of heat performance. If not the coil of this heat out, it will inevitably make the coil and the iron core of the heat accumulated in the more and more and make the iron core internal temperature, which will damage the coil outside the solid insulation, so as to burn the coil. If the use of transformer oil, then this part of the heat generated inside the coil, first of all, is absorbed by the oil, and then through the circulation of the oil and make the heat emitted, which can ensure the safe operation of the equipment.
Parameter:
Sports Event | Quality Indicators | measured value | Test Methods |
Functional characteristics | |||
Pour Point/°C | -50 | -57.5 | ISO 3016 |
Kinematic viscosity (40℃)/(m㎡/s) | ≯12 | 9.52 | ISO 3104 |
Kinematic viscosity (-10°C)/(mm²/s) | ≯1800 | 1028 | ISO 3104 |
Water content/(mg/kg) | ≯30/40 | 9.0 | IEC 60814 |
Breakdown voltage/kV (untreated oil) | ≮30 | 64.5 | IEC 60156 |
Density (20°C)/(g/ml) | ≯895 | 886 | ISO 12185 |
Dielectric loss factor (90°C) | ≯0.005 | 0.0005 | IEC 60247 |
Refining/stabilizing properties | |||
exterior condition | Clear and transparent, free of sediment and suspension (of atmospheric pollution) | Clear and transparent, free of sediment and suspension (of atmospheric pollution) | visual assessment |
Acid value (mgKOH/g) | ≯0.01 | 0.0008 | IEC 62021- 1 |
Interfacial tension/(mN/m) | No general requirements | 45.3 | ISO 6295 |
Total sulfur content (mass fraction)/% | No general requirements | No general requirements | ISO 14596 |
corrosive sulfur | non-corrosive | non-corrosive | DIN 51353 |
Content of antioxidant additives (mass fraction)/percent Oil with antioxidant additives (U) | ≯0.08 | 0.065 | IEC 60666 |
2-Furfural content/(mg/kg) | ≯0.1 | 0.012 | IEC 61198 |
Operational characteristics | |||
Oxidation stability (120°C) Test time: 332h | - | - | - |
--Total acid value (in KOH)/(mg/g) | ≯1.2 | 0.04 | IEC 61125 Act C |
--Oil sludge (mass fraction)/% | ≯0.8 | 0.020 | IEC 61125 Act C |
--Dielectric loss factor (90°C) | ≯0.500 | 0.004 | IEC 60247 |
Gassing/(mm/min) | No general requirements | No general requirements | IEC 60628 |
Health Safety and Environmental Characteristics (HSE) | |||
Flash point (closed)/°C | ≮135 | 148.2 | ISO 2719 |
PCA content (mass fraction)/% | ≯3 | 0.8 | BS 2000 Part 346 |
Polychlorinated biphenyl (PCB) content/(mass fraction)(mg/kg) | undetectable | undetectable | IEC 61619 |
1. Applicable Industry
Drilling equipment: Transformer oil acts as a lubricant, reducing friction and wear while maintaining equipment stability in high temperature environments.
Oilfield Electrical Equipment: In oilfield electrical equipment, transformer oil provides insulation and cooling to ensure reliability in harsh environments.
Electric Locomotives: Transformer oil is used in the electrical systems of electric locomotives to provide insulation, ensure the safe transmission of electric current, and help dissipate heat.
Signal Systems: In railroad signaling equipment, transformer oil is used to insulate and ensure the efficiency and safety of the signaling system.
2. Oil Change Inspection
Operational condition and empirical judgment: Consider the transformer's operating history and maintenance records. If the transformer has experienced frequent failures or degraded performance, it may be necessary to check the quality of the oil and consider replacement. Judgement based on the design life and age of the transformer. If the transformer is approaching or exceeding its design life, it may be necessary to consider changing the transformer oil to ensure its continued safe operation.
Own Factory
Haikun Petrochemical, with its unique business philosophy, stands out in the industry.
Employees at Working
Laboratory technicians at Haikun are experts in industrial oil performance evaluation. Their professional judgment improves product quality.
Canned Oil Products
Our firm, Haikun, is well - versed in packing for international sea - freight shipping. We use 200L steel barrels and 20000L flexitanks, and have efficient packing mechanisms for transformer - related items.
Transportation
With reliable transportation, Haikun Petrochemical is proficient in sea freight. We send insulating oils to Russia, South America, and across the African continent.
Enterprise Culture
Convinced that continuous learning is essential for keeping pace with the times, we encourage our employees to remain passionate about learning, actively absorb new knowledge and skills, and continuously improve their overall qualities, thereby injecting new vitality into the enterprise's development journey.
Customer Testimonials
The insulating oil I bought from Haikun Petrochemical is of high quality. They value customers and have great products. The parameters are correct, and the assay sheets are reliable. The purchase was smooth. - Central Asia, Musabekov Bakhtiyar