Anti-Impact Transformer Oil for Energy Storage Systems
This insulating oil is developed for specific use cases such as new energy energy storage converters and oil-immersed transformers, exceeding the performance restrictions of traditional products. It maintains stable operation between -40℃ and 120℃: no congelation at low temperatures and no deterioration at high temperatures, making it compatible with extreme climatic conditions and dense energy storage cycle operations. A low dielectric loss factor, together with anti-gas evolution technology, reduces gas buildup in energy storage systems and lessens maintenance requirements.
Product Details:Anti-Impact Transformer Oil for Energy Storage Systems
Designed for heat-producing equipment like photovoltaic energy storage converters and high-power distribution transformers, this insulating oil optimizes its heat dissipation and fluidity. It enables fast internal temperature balancing of equipment through effective thermal conduction, reducing maintenance concerns arising from heat accumulation. At the same time, it circulates smoothly even in the compact oil circuit spaces of equipment, without hindering heat dissipation efficiency. Besides, the product utilizes eco-friendly raw materials and processes, leaving no hazardous components behind. After application, it can be recycled and repurposed via professional technology, balancing equipment operational stability and ecological protection needs, and adapting to the long-term development of new energy and urban power grids.
Parameter:
Sports Event | GB2536-11 1-30°C (general purpose) Quality indicators | Typical properties | Test Methods
|
Minimum Cold Commissioning Temperature (LCSET)/°C | -30 | - | - |
Functional characteristics | |||
Pour Point/°C | ≯-40 | -51 | GB/T 3535 |
Kinematic viscosity (40°C)/(mm²/s) | ≯12 | 9.2 | GB/T 265 |
Kinematic viscosity (-30°C)/(mm²/s) | ≯1800 | 1449 | |
Water content/(mg/kg) | ≯30 | 19 | GB/T 7600 |
Breakdown voltage/kV | ≮30 | 66 | GB/T 507 |
Density (20°C)/(kg/m³) | ≯895 | 886.0 | SH/T 0604 |
Dielectric loss factor (90°C) | ≯0.005 | 0.0008 | GB/T 5654 |
Refining/stabilizing properties | |||
exterior condition | clear and transparent | clear and transparent | visual assessment |
Acid value (as KOH)/(mg/g) | ≯0.01 | <0.01 | NB/SH/T 0836 |
Water-soluble acids or bases | not have | not have | GB/T 259 |
Interfacial tension/(mN/m) | ≮40 | 46 | GB/T 6541 |
corrosive sulfur | non-corrosive | non-corrosive | SH/T0804 |
Content of antioxidant (mass fraction)/% | 0.08~0.40 | 0.30 | NB/SH/T0802 |
2-Furfural content/(mg/kg) | ≯0.1 | <0.05 | NB/SH/T0812 |
Operational characteristics | |||
Oxidation stability (120°C) | - | - | NB/SH/T 0811 |
Test time: 500h | - | - | |
--Total acid value (in KOH)/(mg/g) | ≯1.2 | 0.19 | |
--Oil sludge (mass fraction)/% | ≯0.8 | 0.03 | |
--Dielectric loss factor (90°C) | ≯0.500 | 0.051 | GB/T 5654 |
HSE Characteristics | |||
Flash point (closed)/°C | ≮135 | 142 | GB/T 261 |
PCA content (mass fraction)/% | ≯3 | <3 | NB/SH/T 0838 |
Polyoxybiphenyl (PCB) content/(mg/kg) | undetectable | not detected | SH/T 0803 |
1. Oil Change Inspection
Moisture Assessment: Evaluate the moisture content in the oil, since moisture is a prevalent contaminant that can accelerate the aging of transformer oil.
Breakdown Voltage Assessment: It is important to measure the breakdown voltage. A reduction in this voltage may signify that the oil quality has declined and requires replacement.
Loss Factor Evaluation: An increase in the Loss Factor could be an indication that the oil is either contaminated or has aged.
2. Factors Affecting Service Life
For the transformer oil to have an extended service life, it is necessary to frequently inspect the sealing of the oil filling apparatus, the performance of the oil storage cabinet, and the breather (hygroscope). Additionally, checking that the oil color and quantity are normal before filling the transformer is crucial. These actions help ensure the stable performance of transformer oil, thus prolonging its lifespan.
Own Factory
The company, Haikun, produces transformer oil and other lubricants with modern technology.
Employees at Working
Haikun's foreign trade employees are proficient in industrial oil export packaging. Their professionalism ensures product protection during shipping.
Canned Oil Products
We at Haikun are pros at packing for sea - freight logistics. We pack transformer and insulating oils in 200L iron barrels and 20000L flexitanks, with attention to detail in packing.
Transportation
Haikun Petrochemical Technology Co., Ltd. has a mature sea - freight system. We ship transformer - related products to Russia, South America, and multiple African markets.
Enterprise Culture
We promote the corporate culture centered around “responsibility” and inspire our employees to shoulder responsibilities and confront challenges. When difficulties arise, instead of retreating or evading, we actively look for solutions to jointly drive the enterprise's development.
Customer Testimonials
Haikun Petrochemical's industrial lubricants have been working great for me. They listen to customers and ensure product quality. The parameters are correct, and the assay is real. The sales team helped me a lot. - Southeast Asia, Lim Wei Ling
In substation corners and through the grid’s veins, our transformer oil moves softly. It doesn’t make the soil grieve when spilled, doesn’t leave groundwater tossing with residues, and there’s no PCB shadow lurking. From towns to countryside, workshops to wilderness, it safeguards every area it traverses, carrying its green genes.