Low-Temp Startup Transformer Oil
Transformer oil, a specialized oil for electrical equipment like transformers, is usually composed of mineral or synthetic oils and has two vital properties. On one side, it has excellent insulation performance, acting as an insulating barrier in electrical equipment to ensure safe isolation of components in high-voltage environments and prevent current from leaking. On the other side, its good heat dissipation capacity can timely remove the heat generated by equipment operation, maintaining stable equipment operation and ensuring the reliable and efficient operation of the power system.
Product Details:Low-Temp Startup Transformer Oil
With a specialized deep hydrogenation technique, this product achieves a sulfur content of less than 0.001% and aromatic hydrocarbon content of less than 5%, adhering to EU environmental criteria. Its recycling rate exceeds 95%. In addition, optimized for the compact structure of urban power grid equipment, the product refines its fluidity to upgrade heat dissipation capabilities. This not only supports extending equipment service life by over 30% but also ensures comprehensive compatibility across performance, environmental protection, and real-world usage scenarios.
Parameter:
Sports Event | Quality Indicators | Measured value | Test Methods |
Functional characteristics | |||
Pour Point/°C | -50 | -57.5 | ISO 3016 |
Kinematic viscosity (40℃)/(m㎡/s) | ≯12 | 9.52 | ISO 3104 |
Kinematic viscosity (-10°C)/(mm²/s) | ≯1800 | 1028 | ISO 3104 |
Water content/(mg/kg) | ≯30/40 | 9.0 | IEC 60814 |
Breakdown voltage/kV (untreated oil) | ≮30 | 64.5 | IEC 60156 |
Density (20°C)/(g/ml) | ≯895 | 886 | ISO 12185 |
Dielectric loss factor (90°C) | ≯0.005 | 0.0005 | IEC 60247 |
Refining/stabilizing properties | |||
Exterior condition | Clear and transparent, free of sediment and suspension (of atmospheric pollution) | Clear and transparent, free of sediment and suspension (of atmospheric pollution) | Visual assessment |
Acid value (mgKOH/g) | ≯0.01 | 0.0008 | IEC 62021- 1 |
Interfacial tension/(mN/m) | No general requirements | 45.3 | ISO 6295 |
Total sulfur content (mass fraction)/% | No general requirements | No general requirements | ISO 14596 |
Corrosive sulfur | non-corrosive | non-corrosive | DIN 51353 |
Content of antioxidant additives (mass fraction)/percent Oil with antioxidant additives (U) | ≯0.08 | 0.065 | IEC 60666 |
2-Furfural content/(mg/kg) | ≯0.1 | 0.012 | IEC 61198 |
Operational characteristics | |||
Oxidation stability (120°C) Test time: 332h | - | - | - |
--Total acid value (in KOH)/(mg/g) | ≯1.2 | 0.04 | IEC 61125 Act C |
--Oil sludge (mass fraction)/% | ≯0.8 | 0.020 | IEC 61125 Act C |
--Dielectric loss factor (90°C) | ≯0.500 | 0.004 | IEC 60247 |
Gassing/(mm/min) | No general requirements | No general requirements | IEC 60628 |
Health Safety and Environmental Characteristics (HSE) | |||
Flash point (closed)/°C | ≮135 | 148.2 | ISO 2719 |
PCA content (mass fraction)/% | ≯3 | 0.8 | BS 2000 Part 346 |
Polychlorinated biphenyl (PCB) content/(mass fraction)(mg/kg) | undetectable | undetectable | IEC 61619 |
1. Oil Change Inspection
Oil Appearance Check: Look for visible impurities or deposits in the oil, which could be caused by aging, oxidation, or contamination. If the oil appears excessively dark or cloudy, it may be a sign that it requires replacement.
Testing Insulation Resistance: It is important to carry out an insulation resistance test. A decrease in resistance may reveal the presence of moisture or contaminants in the oil, adversely affecting its insulating properties.
2. Factors Affecting Service Life
Regular quality analysis and testing are important for maintaining the service life of transformer oil. This involves checking insulation resistance, absorption ratio, polarization index, dielectric loss, winding leakage current, and the oil's microwater content. A detailed analysis of these results can help determine if the oil is damp, contains impurities, or is aging. If issues are identified, the first step might be to regenerate the oil through filtration. However, if this method is ineffective or the oil quality is severely compromised, replacing it with new transformer oil is necessary.
Own Factory
Specializing in power and textile, Haikun provides suitable lubricant solutions.
Employees at Working
Haikun's foreign trade employees are well - informed about industrial oil new product development. Their analysis helps us innovate.
Canned Oil Products
We at Haikun are experts in packing for overseas sea - freight operations. We use 200L steel drums and 20000L flexitanks, and have reliable packing procedures for transformer oils, with proper packing in shipping containers.
Transportation
Haikun Petrochemical Technology Co., Ltd. has a stable shipping network. We're experienced in sea freight, sending transformer oils to South America, Africa, and Russia.
Enterprise Culture
We are firmly convinced that details decide success or failure. In our work, we focus on each and every detail and strive for perfection. It is this unwavering pursuit of details that has enabled our products and services to gain extensive praise from customers.
Customer Testimonials
The insulating oil I purchased from Haikun is of excellent quality. They respect customer needs and maintain product quality. The parameters match, and the assay is professional. The sales service was top - notch. - Central Asia, Karimov Dilshod
"Environmental friendliness" is woven into every step of making our transformer oil: we firmly eliminate harmful elements like PCBs and fully meet green standards from the EU, US, and global bodies—such as IEC 62770 specifications for biodegradable insulation fluids. As it moves through equipment, it leaves no hint of pollution, only a green mark. Choosing this product lets electricity’s power always cradle nature softly.