Antioxidant Enhanced Insulation Liquid
As a critical insulating medium for electrical equipment, transformer oil is mostly refined and extracted from petroleum, with alkanes and cycloalkanes as its main constituents. Its excellent electrical insulation can effectively separate the high-voltage components within the transformer to prevent leakage and short circuits. Thanks to its good thermal conductivity, the heat generated during the transformer's operation is quickly dissipated, avoiding overheating and damage. Additionally, it has a certain arc-extinguishing capacity, which can quickly quench the arc when the switching appliance cuts off the current and generates an arc.
Product Details:Antioxidant Enhanced Insulation Liquid
Transformer is an important piece of equipment in the power grid, transformer can operate normally in relation to the safety of the power grid, and the transformer oil is directly related to the reliability of transformer operation. Therefore, we must do a good job of transformer oil selection, use and management work to ensure that the transformer operation safety. Selection of the principle, first of all, is to consider the performance of oil, quality to meet the equipment voltage level, the location of the ambient temperature and other factors on the oil requirements, in addition, should also consider the compatibility of oil and other relevant insulating materials.
Parameter:
Sports Event | Quality Indicators | measured value | Test Methods |
Functional characteristics | |||
Pour Point/°C | -50 | -57.5 | ISO 3016 |
Kinematic viscosity (40℃)/(m㎡/s) | ≯12 | 9.52 | ISO 3104 |
Kinematic viscosity (-10°C)/(mm²/s) | ≯1800 | 1028 | ISO 3104 |
Water content/(mg/kg) | ≯30/40 | 9.0 | IEC 60814 |
Breakdown voltage/kV (untreated oil) | ≮30 | 64.5 | IEC 60156 |
Density (20°C)/(g/ml) | ≯895 | 886 | ISO 12185 |
Dielectric loss factor (90°C) | ≯0.005 | 0.0005 | IEC 60247 |
Refining/stabilizing properties | |||
exterior condition | Clear and transparent, free of sediment and suspension (of atmospheric pollution) | Clear and transparent, free of sediment and suspension (of atmospheric pollution) | visual assessment |
Acid value (mgKOH/g) | ≯0.01 | 0.0008 | IEC 62021- 1 |
Interfacial tension/(mN/m) | No general requirements | 45.3 | ISO 6295 |
Total sulfur content (mass fraction)/% | No general requirements | No general requirements | ISO 14596 |
corrosive sulfur | non-corrosive | non-corrosive | DIN 51353 |
Content of antioxidant additives (mass fraction)/percent Oil with antioxidant additives (U) | ≯0.08 | 0.065 | IEC 60666 |
2-Furfural content/(mg/kg) | ≯0.1 | 0.012 | IEC 61198 |
Operational characteristics | |||
Oxidation stability (120°C) Test time: 332h | - | - | - |
--Total acid value (in KOH)/(mg/g) | ≯1.2 | 0.04 | IEC 61125 Act C |
--Oil sludge (mass fraction)/% | ≯0.8 | 0.020 | IEC 61125 Act C |
--Dielectric loss factor (90°C) | ≯0.500 | 0.004 | IEC 60247 |
Gassing/(mm/min) | No general requirements | No general requirements | IEC 60628 |
Health Safety and Environmental Characteristics (HSE) | |||
Flash point (closed)/°C | ≮135 | 148.2 | ISO 2719 |
PCA content (mass fraction)/% | ≯3 | 0.8 | BS 2000 Part 346 |
Polychlorinated biphenyl (PCB) content/(mass fraction)(mg/kg) | undetectable | undetectable | IEC 61619 |
1. Applicable Industry
Industrial motors: In high power motors, transformer oil is used for insulation and cooling to prevent overheating and to ensure efficient operation of the motor.
Generators: In generators, transformer oils help maintain stable operating temperatures and reduce failure rates.
Communications Equipment: In military communications equipment, transformer oil provides insulation and cooling to ensure reliability in high temperature and vibration environments.
Avionics: In aircraft electronics, transformer oils are used to insulate and dissipate heat, ensuring proper operation at high altitudes and in extreme weather conditions.
2. Factors Affecting Service Life
The design life of a transformer is an important determinant of the transformer oil's lifespan. Generally, this design life is calculated based on the expected longevity of the oil. Thus, during its design life, the transformer oil should be able to meet the operational needs of the transformer. Environmental conditions such as high temperatures, humidity, and pollution also play a role in the service life of transformer oil. In adverse environments, the oil may age more quickly, thereby shortening its lifespan.
Own Factory
The company, Haikun, provides integrated technical and product solutions.
Employees at Working
Haikun's foreign trade workers are skilled in industrial oil contract negotiation. Their skills protect our company's interests.
Canned Oil Products
Haikun Petrochemical Technology Co., Ltd. has extensive experience in packing for overseas sea - freight logistics. We use 200L iron containers and 20000L liquid bags to ensure safe shipment of insulating oils.
Transportation
Our firm, Haikun, has mastered the sea - freight process. We use trusted channels to ship transformer - related products to Russia and multiple African and South American countries.
Enterprise Culture
We champion the "customer - focused" business belief. We always place customers' needs at the highest position. Through thorough comprehension of customer needs, we constantly optimize our products and services, striving to be outstanding in the intense market competition and win the support of customers.
Customer Testimonials
Transformer oil from Haikun is excellent. They value customers and have high - performance products. The parameters are accurate, and the assay sheets are reliable. The buying experience was good. - Europe, Green Sarah