Natural Ester Transformer Oil U-20 Model

The product has superior insulating properties and much higher dielectric strength than air. The insulating material is immersed in oil, which not only improves the insulating strength, but also protects it from the erosion of moisture. Transformer oil can effectively prevent short-circuit failures within the equipment and ensure the normal operation of electrical equipment.


Product Details

Product Details:Natural Ester Transformer Oil U-20 Model

Transformer oil has excellent thermal stability, and can effectively reduce the internal temperature of the equipment when running for a long time to ensure the normal operation of the equipment. In the long operation of electrical equipment, equipment will produce a large amount of internal heat, transformer oil as a coolant, through the oil convection up and down, the heat will be dissipated through the radiator.

 Natural Ester Transformer Oil U-20 Model

PARAMETER

Sports Event

IEC60296:2020 TVBUs

(LCSET-30°C) Quality indicators

Typical properties

Test Methods

Functional characteristics

Pour Point/°C

≯-30

-35

ISO 3016

Kinematic viscosity (40°C)/(mm²/s)

≯12

10.1

ISO 3104

Kinematic viscosity (-30°C)/(mm²/s)

≯1800

1500

Water content/(mg/kg)

≯30

22

IEC 60814

Breakdown voltage/kV

-

-

IEC 60156

-Untreated oil

≮30

40-70

-Treated oil

≮70

>70

Density (20°C)/(kg/m³)

≯895

883

ISO 12185

Dielectric loss factor (90°C)

≯0.005

<0.001

IEC 60247

Refining/stabilizing properties

saturation (color theory)

≯1.5

0.5

ISO 2049

exterior condition

Clear and transparent, no precipitation

Clear and transparent, no precipitation

visual assessment

Acid value/(mgKOH/g)

≯0.01

<0.01

IEC 62021-1

Interfacial tension/(mN/m)

≮40

44

ASTMD 971

corrosive sulfur

non-corrosive

non-corrosive

DIN 51353

corrosive sulfur

-

non-corrosive

ASTMD 1275B

Potentially corrosive sulfur

non-corrosive

non-corrosive

IEC62535

DBDS/(mg/kg)

Not detectable (<5)

not detected

IEC 62697-1

Antioxidant content/%

Not detectable (<0.01)

not detected

IEC 60666

Metal passivator/(mgkg)

Not detectable (<5)

not detected

IEC 60666

2-Furfural content and related substances (single component) (mg/kg)

Not detectable (<0.05)

<0.01

IEC 61198

Operational characteristics

Chlorine stability (164h)

-

-

IEC 61125

--Total acid value (mg KOH/g)

≯1.2

0.70

-- Oil sludge/%

≯0.8

0.35

--Dielectric loss factor (90°C)

≯0.500

0.040

IEC 60247

HSE Characteristics

Flash point (closed)/°C

≮135

145

ISO 2719

PCA content/%

<3

<3

IP 346

Polychlorinated biphenyl (PCB) content/(mg/kg)

undetectable

undetectable

IEC 61619


1. Important Indicators

(1) Breakdown Voltage: Indicates the maximum voltage that the insulating oil can withstand under certain conditions. A high breakdown voltage means that the oil has better electrical insulation properties. For example, some insulating oils may have a breakdown voltage of 48kV (2.5mm spacing).

(2) Dielectric Loss Factor: A measure of the power dissipated by the dielectric material of an insulating oil when subjected to an AC voltage. A low dielectric loss factor indicates that the electrical properties of the insulating oil are superior.

(3) Interfacial Tension: Indicates the surface tension between the insulating oil and different substances. The magnitude of interfacial tension affects the distribution and wetting properties of the insulating oil in the equipment.

(4) Closed Flash Point:Indicates the ignition point of the insulating oil,i.e.the lowest temperature at which a mixture of vapour and air on the oil surface will flash when close to a flame.Higher flash point means higher safety of insulating oil.For example,some insulating oils may have a closed flash point higher than 140°C.

2. Storage Conditions

Temperature and Humidity:For optimal storage of transformer oil, it is crucial to maintain the ambient temperature within the range of 15°C to 35°C, with a relative humidity between 45% and 65%. This ensures that the oil is not exposed to adverse conditions such as high temperatures or humidity, thereby preserving its superior performance.

 

Own Factory

Natural Ester Transformer Oil U-20 Model


Employees at Working

Natural Ester Transformer Oil U-20 Model


Canned Oil Products

Natural Ester Transformer Oil U-20 Model


Transportation

Natural Ester Transformer Oil U-20 Model


SERVICE

Production Philosophy

Our product philosophy is relentless pursuit of excellence. Haikun ensures every aspect from R&D to installation and after-sales is tailored to customers' needs, delivering high-value products. We promise that every investment will yield unexpected returns, ensuring customers enjoy unparalleled quality.

Customer Service

Respect customers, products and services should be based on customer needs, and provide customers with better value choices for products and services.To understand customers, one should research, design, and improve services from their perspective.

 

FAQ:

Q: Are your prices competitive?

A: We are committed to offering competitive prices while ensuring the quality of our products and the excellence of our services. We will provide customers with reasonable price plans based on factors such as market conditions and order volume.

 

Q: What are the payment methods?

A4: We accept wire transfer. Specific payment methods can be determined according to customers' needs and preferences.

 

Q: What is the production lead time for the products?

A: The production lead time is usually 3 weeks, which may be adjusted according to the order quantity and the actual situation of the production line. We will try our best to shorten the production cycle to meet customers' needs.


Leave your messages

Related Products

x

Popular products

x