Dielectric Greases And Insulating Fluids

Our company's transformer oil boasts minimal volatility, ensuring consistent oil levels within equipment and mitigating the risk of accidents stemming from oil depletion. Furthermore, its robust corrosion resistance safeguards against chemical reactions and erosion, underlining its exceptional safety standards and premium quality.


Product Details

Product Details:Dielectric Greases And Insulating Fluids

The transformer oil manufactured by us exhibits remarkable resilience to oxidation and decomposition even at high temperatures and in oxidizing conditions, ensuring sustained chemical stability and long-lasting performance. Additionally, the precise addition of antioxidants bolsters its chemical stability, enabling it to efficiently insulate, cool, and safeguard the machinery, achieving outstanding functionality.


Dielectric Greases And Insulating Fluids


PARAMETER

Sports Event

Quality Indicators

measured value

Test Methods

Functional characteristics

Pour Point/°C

-20

-36.8

ISO 3016

Kinematic viscosity(40℃)/(m㎡/s)

≯12

9.13

 

ISO 3104

Kinematic viscosity(-10°C)/(mm²/s)

≯1800

1089

ISO 3104

Water content/(mg/kg)

≯30/40

6.3

IEC 60814

Breakdown voltage/kV(untreated oil)

≮30

62.4

IEC 60156

Density(20°C)/(g/ml)

≯895

886

ISO 12185

Dielectric loss factor(90°C)

≯0.005

0.00041

IEC 60247

Refining/stabilizing properties

exterior condition

Clear and transparent,free of sediment and

suspension(of atmospheric pollution)

Clear and transparent,free of sediment and

suspension(of atmospheric pollution)

visual assessment

Acid value(mgKOH/g)

≯0.01

0.0008

IEC 62021-

1

Interfacial tension/(mN/m)

No general requirements

46

ISO 6295

Total sulfur content(mass fraction)/%

No general requirements

No general requirements

ISO 14596

corrosive sulfur

non-corrosive

non-corrosive

DIN 51353

Content of antioxidant additives(mass fraction)/percent

Oil with antioxidant additives(U)

≯0.08

0.059

IEC 60666

2-Furfural content/(mg/kg)

≯0.1

0.012

IEC 61198

Operational characteristics

Oxidation stability(120°C)

Test time:332h

-

-

-

--Total acid value(in KOH)/(mg/g)

≯1.2

0.04

IEC 61125

Act C

--Oil sludge(mass fraction)/%

≯0.8

0.020

IEC 61125 Act C

--Dielectric loss factor(90°C)

≯0.500

0.004

IEC 60247

Gassing/(mm/min)

No general requirements

No general requirements

IEC 60628

Health Safety and Environmental Characteristics(HSE)

Flash point(closed)/°C

≮135

147.3

ISO 2719

PCA content(mass fraction)/%

≯3

0.8

BS 2000

Part 346

Polychlorinated biphenyl(PCB)content/(mass fraction)(mg/kg)

undetectable

undetectable

IEC 61619


1. Market Trends and Insights

In contemporary times, transformer safety concerns persist across both advanced and emerging economies, posing varying degrees of challenges. Transformer malfunctions often entail arcs, discharges, and intense combustion, subsequently triggering short circuits, equipment failures, power outages, and potentially disastrous fires with human casualties. Hence, ensuring the secure and uninterrupted functioning of transformers is a global priority.

The primary insulating medium within transformers, transformer oil, is pivotal to the safe operation of transformers and the broader power grid. Since 1887, mineral oil has been the traditional choice, while polychlorinated biphenyls (PCBs) emerged as a synthetic alternative in 1931, and silicone oil joined the fray as an insulating fluid in 1956. Given its abundant sources, affordability, and exceptional performance, mineral transformer oil continues to dominate the field, significantly contributing to the insulation of electrical infrastructure.


2. Physical and Chemical Performance Testing

Moisture Level: Moisture significantly influences the insulating capabilities of transformer oil, necessitating moisture content testing to maintain stable insulation properties.

Viscosity Factor: The viscosity of transformer oil is a crucial determinant of its cooling efficiency. Regular viscosity checks ensure optimal heat dissipation at high temperatures while preserving good fluidity at low temperatures.

Flammability Thresholds: Flash point and ignition point serve as benchmarks for evaluating transformer oil's combustion resistance. Lower values indicate heightened volatility and flammability, thereby escalating fire hazards.

 

Own Factory

Dielectric Greases And Insulating Fluids


Employees at Working

Dielectric Greases And Insulating Fluids


Canned Oil Products

Dielectric Greases And Insulating Fluids


Transportation

Dielectric Greases And Insulating Fluids


 

Enterprise Culture

Integrity serves as the bedrock of our corporate identity. We are convinced that sincerity in our interactions fosters long-lasting trust and partnership. Our approach to business underscores open dialogue, consistent delivery on promises, and translating our words into meaningful actions, adhering to the spirit of 'deeds that match words, outcomes that justify efforts,' to jointly cultivate a realm of honest trade.

 

Brand Story

The path to quality improvement is long and arduous, replete with obstacles and setbacks. However, HaiKun Petrochemical's relentless drive for excellence has turned these challenges into stepping stones. We've fortified our quality control infrastructure, meticulously scrutinizing every production step to ensure that every product lot meets the highest standards. Moreover, we've actively embraced state-of-the-art testing equipment and skilled professionals, continuously enhancing our testing capabilities to safeguard product quality. It is this unwavering perseverance in the face of adversity and relentless pursuit of new heights that has enabled HaiKun Petrochemical Technology Co., Ltd. to shine amidst fierce market competition, emerging as a pioneer in the foreign trade of petrochemicals. Our actions have given tangible meaning to the phrase "Challenges Beget Opportunities," setting a fresh benchmark and example for the industry to follow.

 


Leave your messages

Related Products

x

Popular products

x