Dielectric Greases And Insulating Fluids
      
                Our company's transformer oil boasts minimal volatility, ensuring consistent oil levels within equipment and mitigating the risk of accidents stemming from oil depletion. Furthermore, its robust corrosion resistance safeguards against chemical reactions and erosion, underlining its exceptional safety standards and premium quality.
Product Details:Dielectric Greases And Insulating Fluids
The transformer oil manufactured by us exhibits remarkable resilience to oxidation and decomposition even at high temperatures and in oxidizing conditions, ensuring sustained chemical stability and long-lasting performance. Additionally, the precise addition of antioxidants bolsters its chemical stability, enabling it to efficiently insulate, cool, and safeguard the machinery, achieving outstanding functionality.
PARAMETER:
| Sports Event | Quality Indicators | measured value | Test Methods | 
| Functional characteristics | |||
| Pour Point/°C | -20 | -36.8 | ISO 3016 | 
| Kinematic viscosity(40℃)/(m㎡/s) | ≯12 | 9.13 
 | ISO 3104 | 
| Kinematic viscosity(-10°C)/(mm²/s) | ≯1800 | 1089 | ISO 3104 | 
| Water content/(mg/kg) | ≯30/40 | 6.3 | IEC 60814 | 
| Breakdown voltage/kV(untreated oil) | ≮30 | 62.4 | IEC 60156 | 
| Density(20°C)/(g/ml) | ≯895 | 886 | ISO 12185 | 
| Dielectric loss factor(90°C) | ≯0.005 | 0.00041 | IEC 60247 | 
| Refining/stabilizing properties | |||
| exterior condition | Clear and transparent,free of sediment and suspension(of atmospheric pollution) | Clear and transparent,free of sediment and suspension(of atmospheric pollution) | visual assessment | 
| Acid value(mgKOH/g) | ≯0.01 | 0.0008 | IEC 62021- 1 | 
| Interfacial tension/(mN/m) | No general requirements | 46 | ISO 6295 | 
| Total sulfur content(mass fraction)/% | No general requirements | No general requirements | ISO 14596 | 
| corrosive sulfur | non-corrosive | non-corrosive | DIN 51353 | 
| Content of antioxidant additives(mass fraction)/percent Oil with antioxidant additives(U) | ≯0.08 | 0.059 | IEC 60666 | 
| 2-Furfural content/(mg/kg) | ≯0.1 | 0.012 | IEC 61198 | 
| Operational characteristics | |||
| Oxidation stability(120°C) Test time:332h | - | - | - | 
| --Total acid value(in KOH)/(mg/g) | ≯1.2 | 0.04 | IEC 61125 Act C | 
| --Oil sludge(mass fraction)/% | ≯0.8 | 0.020 | IEC 61125 Act C | 
| --Dielectric loss factor(90°C) | ≯0.500 | 0.004 | IEC 60247 | 
| Gassing/(mm/min) | No general requirements | No general requirements | IEC 60628 | 
| Health Safety and Environmental Characteristics(HSE) | |||
| Flash point(closed)/°C | ≮135 | 147.3 | ISO 2719 | 
| PCA content(mass fraction)/% | ≯3 | 0.8 | BS 2000 Part 346 | 
| Polychlorinated biphenyl(PCB)content/(mass fraction)(mg/kg) | undetectable | undetectable | IEC 61619 | 
1. Market Trends and Insights
In contemporary times, transformer safety concerns persist across both advanced and emerging economies, posing varying degrees of challenges. Transformer malfunctions often entail arcs, discharges, and intense combustion, subsequently triggering short circuits, equipment failures, power outages, and potentially disastrous fires with human casualties. Hence, ensuring the secure and uninterrupted functioning of transformers is a global priority.
The primary insulating medium within transformers, transformer oil, is pivotal to the safe operation of transformers and the broader power grid. Since 1887, mineral oil has been the traditional choice, while polychlorinated biphenyls (PCBs) emerged as a synthetic alternative in 1931, and silicone oil joined the fray as an insulating fluid in 1956. Given its abundant sources, affordability, and exceptional performance, mineral transformer oil continues to dominate the field, significantly contributing to the insulation of electrical infrastructure.
2. Physical and Chemical Performance Testing
Moisture Level: Moisture significantly influences the insulating capabilities of transformer oil, necessitating moisture content testing to maintain stable insulation properties.
Viscosity Factor: The viscosity of transformer oil is a crucial determinant of its cooling efficiency. Regular viscosity checks ensure optimal heat dissipation at high temperatures while preserving good fluidity at low temperatures.
Flammability Thresholds: Flash point and ignition point serve as benchmarks for evaluating transformer oil's combustion resistance. Lower values indicate heightened volatility and flammability, thereby escalating fire hazards.
Own Factory
Employees at Working
Canned Oil Products
Transportation
Enterprise Culture
Integrity serves as the bedrock of our corporate identity. We are convinced that sincerity in our interactions fosters long-lasting trust and partnership. Our approach to business underscores open dialogue, consistent delivery on promises, and translating our words into meaningful actions, adhering to the spirit of 'deeds that match words, outcomes that justify efforts,' to jointly cultivate a realm of honest trade.
Brand Story
The path to quality improvement is long and arduous, replete with obstacles and setbacks. However, HaiKun Petrochemical's relentless drive for excellence has turned these challenges into stepping stones. We've fortified our quality control infrastructure, meticulously scrutinizing every production step to ensure that every product lot meets the highest standards. Moreover, we've actively embraced state-of-the-art testing equipment and skilled professionals, continuously enhancing our testing capabilities to safeguard product quality. It is this unwavering perseverance in the face of adversity and relentless pursuit of new heights that has enabled HaiKun Petrochemical Technology Co., Ltd. to shine amidst fierce market competition, emerging as a pioneer in the foreign trade of petrochemicals. Our actions have given tangible meaning to the phrase "Challenges Beget Opportunities," setting a fresh benchmark and example for the industry to follow.


 
                                            
                                                                                        
                                         
                                            
                                                                                        
                                         
                                            
                                                                                        
                                        




 
                   
                  