Thermally Upgraded Naphthenic Insulation Oil
From the general concept, transformer oil is divided into from paraffinbased crude oil and naphthenic crude oil production, but with the development of hydrogenation and reforming process, paraffinbased crude oil can also produce pour point and naphthenic crude oil with Wanmei transformer oil. Evaluation of transformer oil base oil, in addition to the conventional physical and chemical properties, the most common method of carbon structure (also known as the structure of the family composition). The socalled carbonbased structure, that is, the composition of the complex base oil is viewed as a single molecule by the aromatic ring, naphthenic ring and alkyl side chain of the three structural components, Cp value refers to the carbon atoms on the alkyl side chain of the entire molecule as a percentage of the total carbon.
Product Details:Thermally Upgraded Naphthenic Insulation Oil
When insulating oils are utilized in transformers, capacitors, and cables, it is advisable to prioritize mineral insulating oils derived from naphthenic crude oils. These oils must remain stable in both physical and chemical properties when subjected to electromagnetic fields and other environmental conditions to ensure the safety and reliability of electrical equipment. The refining process for these insulating oils should be based on naphthenic hydrocarbons as the primary components, including a sufficient amount of stable aromatic hydrocarbons, while aiming to remove paraffinic hydrocarbons that are prone to cleavage due to their long straightchain structure.
Parameter:
Sports Event | Quality Indicators | Measured value | Test Methods |
Functional characteristics | |||
Pour Point/°C | -50 | -57.5 | ISO 3016 |
Kinematic viscosity (40℃)/(m㎡/s) | ≯12 | 9.52
| ISO 3104 |
Kinematic viscosity (-10°C)/(mm²/s) | ≯1800 | 1028 | ISO 3104 |
Water content/(mg/kg) | ≯30/40 | 9.0 | IEC 60814 |
Breakdown voltage/kV (untreated oil) | ≮30 | 64.5 | IEC 60156 |
Density (20°C)/(g/ml) | ≯895 | 886 | ISO 12185 |
Dielectric loss factor (90°C) | ≯0.005 | 0.0005 | IEC 60247 |
Refining/stabilizing properties | |||
Exterior condition | Clear and transparent, free of sediment and suspension (of atmospheric pollution) | Clear and transparent, free of sediment and suspension (of atmospheric pollution) | Visual assessment |
Acid value (mgKOH/g) | ≯0.01 | 0.0008 | IEC 62021- 1 |
Interfacial tension/(mN/m) | No general requirements | 45.3 | ISO 6295 |
Total sulfur content (mass fraction)/% | No general requirements | No general requirements | ISO 14596 |
Corrosive sulfur | non-corrosive | non-corrosive | DIN 51353 |
Content of antioxidant additives (mass fraction)/percent Oil with antioxidant additives (U) | ≯0.08 | 0.065 | IEC 60666 |
2-Furfural content/(mg/kg) | ≯0.1 | 0.012 | IEC 61198 |
Operational characteristics | |||
Oxidation stability (120°C) Test time: 332h | - | - | - |
--Total acid value (in KOH)/(mg/g) | ≯1.2 | 0.04 | IEC 61125 Act C |
--Oil sludge (mass fraction)/% | ≯0.8 | 0.020 | IEC 61125 Act C |
--Dielectric loss factor (90°C) | ≯0.500 | 0.004 | IEC 60247 |
Gassing/(mm/min) | No general requirements | No general requirements | IEC 60628 |
Health Safety and Environmental Characteristics (HSE) | |||
Flash point (closed)/°C | ≮135 | 148.2 | ISO 2719 |
PCA content (mass fraction)/% | ≯3 | 0.8 | BS 2000 Part 346 |
Polychlorinated biphenyl (PCB) content/(mass fraction)(mg/kg) | undetectable | undetectable | IEC 61619 |
1. Environmental Friendliness of Transformer Oil
Recycling and reuse: Transformer oils can be reprocessed through physical and chemical methods to remove impurities and contaminants, thereby restoring their performance.
Reclaimed Oil: Transformer oils that have been reprocessed can achieve similar properties to new oil, reducing the waste of resources and lowering the need for new raw materials. The use of recycled oil is not only economical, but also reduces the burden on the environment.
2. Factors Affecting Service Life
The lifespan of transformer oil is significantly affected by the design life of the transformer. Typically, the design life is defined based on the expected service life of the oil. Therefore, throughout this design life, the transformer oil should fulfill the operational requirements of the transformer. Additionally, environmental factors like high temperatures, humidity, and pollution can influence the oil's service life. In poor environmental conditions, the aging of the oil accelerates, leading to a shorter lifespan.
Own Factory
Haikun, with 15 300 - square - meter oil tanks, stores a large amount of oil products.
Employees at Working
At Haikun, employees work with enthusiasm in the industrial oil business. Their dedication and cooperation drive the company forward.
Canned Oil Products
With efficient packing methods, Haikun Petrochemical packs transformer - related items in 200L iron drums and 20000L liquid bags for smooth international sea - freight shipping.
Transportation
With reliable transportation channels, Haikun Petrochemical is proficient in global sea shipping. We send insulating oils to various regions, including South America and Africa.
Enterprise Culture
We firmly hold the belief that only continuous learning allows us to keep up with the times' tempo. So, we motivate our employees to maintain their love for learning, actively take on new knowledge and skills, and constantly improve their comprehensive qualities, in an effort to bring new vitality to the enterprise's development process.
Customer Testimonials
Haikun Petrochemical's industrial lubricants are top - of - the - line. They understand customer needs and provide accurate product details. The salesperson guided me well. - South Asia, Singh Amrit