Fully Enclosed Oil Transformers
      
                The oil-immersed transformer is an electrical device utilizing insulating oil as its core insulation method, constructed with an iron core, windings, a tap changer, an oil reservoir, and other components. It serves to transform voltage levels and transmit alternating current energy, boasting a compact design, economical pricing, and robust resistance to climatic conditions.
Product Details:Fully Enclosed Oil Transformers
Oil-immersed transformers boast significant advantages, primarily centered around their high-efficiency energy usage and conservation, as well as impressive insulation performance and reliability. The insulating oil serves a vital role, effectively segregating the windings and safeguarding against electrical arcs, discharges, and other potential issues. Additionally, it stabilizes temperatures, forestalling overheating and extending the transformer's operational life.
PARAMETER:
| Model | Rated Capacity | Typical voltage combinations (kV) | Linkage group labeling | Impedance Voltage | Total weight | Transportation weight | Reference Size(mm) | No-load loss | Load Loss | 
| S(F)Z11-6300/35 | 6300 | oppressive H.V.35~38.5 | YNd11 | 8 | 18 | 13 | 4000*3300*3100 | 5.63 | 36.7 | 
| S(F)Z11-8000/35 | 8000 | 21 | 16 | 4200*3400*3300 | 7.87 | 40.6 | |||
| S(F)Z11- | 10000 | 23 | 17 | 4300*3500*3500 | 9.28 | 48 | |||
| S(F)Z11- | 12500 | 28 | 21 | 4800*3500*3700 | 10.71 | 56.8 | |||
| S(F)Z11- | 16000 | 33 | 24 | 5000*3800*3800 | 13.1 | 70.3 | |||
| S(F)Z11- | 20000 | 38 | 29 | 5300*4000*4000 | 15.5 | 82.7 | |||
| S(F)Z11- | 25000 | 10 | 43 | 33 | 5500*4200*4100 | 18.3 | 97.8 | ||
| S(F)Z11- | 31500 | 50 | 39 | 5800*4400*4300 | 21.8 | 116 | 
1. Preventing Transformer Moisture
(1)Transformer purchased, should immediately ask the power supply bureau to do the handover test; Immediately add moisture absorber, transformer capacity in 100 kVA and above are with moisture absorber. As soon as the transformer is delivered to the site, a moisture absorber should be installed to prevent the internal body from moisture. Monitor the moisture absorber in the silica gel, moisture should be replaced immediately. Moisture absorber in the silica gel, play the role of absorbing moisture, protect the transformer. After moisture absorption, silica gel color change, then need to replace the new dry silica gel.
(2)When ordering should pay attention to, to minimize the storage time of the transformer before power delivery. Transformer manufacturing, storage is very easy to moisture, the longer the storage time the more serious the moisture, so it should be scheduled to minimize the storage time. Capacity in 100 kVA and below small transformer, no moisture absorber device. The oil in the oil pillow is easy to get damp, and the oil pillow accumulates water. In do not send power to store more than six months, or put into operation for more than a year, the transformer oil pillow oil has been serious moisture.
(3)If you want to carry out lifting and transportation, maintenance and refueling, oil valve oil, hanging core and other work, should first through the oil pillow below the oil drain plug to oil pillow in the oil drain, and with a dry cloth to wipe clean, sealed, so as not to make the oil pillow in the dirty oil into the tank.
(4)Transformer operation, should always pay attention to the oil level, oil temperature, voltage, current changes, such as abnormalities should be analyzed in time.
(5)Transformer installation is strictly prohibited with aluminum stranded wire, aluminum rows and other transformer copper guide bar connection, so as not to corrode the guide bar.
2. Installation site layout:
Power transformer overhaul and assembly work is best carried out in the overhaul room. No overhaul room, you need to choose a temporary line of installation sites, the best choice in the transformer near the base platform, so that the transformer in place, but also in the base platform on the ground installation, outdoor site should be tents. Temporary installation site must be easy to transport, the road is flat, there is enough width, the ground should be solid, flat and dry, away from smoke windows and water towers, and the distance from nearby buildings to meet the fire requirements.
CASES
Own Factory
Employees at Working
Transportation
SERVICE
Multimodal Transport Expertise
We provide a wide array of transportation modalities, spanning roads, railways, waterways, and air cargo. We consult on the most suitable modes and routes tailored to our clients' needs and financial constraints. Our global reach guarantees prompt and reliable shipment of goods, irrespective of their origin or destination.
Safety and Environmental Protection
Safety and environmental protection is a social responsibility that chemical companies cannot shirk. We are well aware of the importance of safe production and environmental protection, so we always put safety and environmental protection work in the first place. Through the establishment of a sound safety and environmental protection management system, we ensure that the production process of safety and environmental protection measures are effectively implemented.
FAQ:
Q: How would you describe your company's main operations globally?
A: Our company operates globally, specializing in the acquisition, distribution, and logistical facilitation of imported and exported goods across international borders.
Q: How can we communicate effectively when there are cultural differences between us?
A: We will respect and understand your cultural background, and maintain effective communication with you through email, telephone, video conference and other means. At the same time, we will also provide professional translation services to ensure smooth communication between both parties.
Q: What are the key terms in the contract that I need to pay attention to?
A: In the contract, special attention needs to be paid to key terms such as delivery time, payment method, quality standard, and liability for breach of contract. Both parties should ensure that these terms are clear, specific and in line with relevant laws and regulations.


 
                                            
                                                                                        
                                         
                                            
                                                                                        
                                         
                                            
                                                                                        
                                        




 
                   
                  