Insulating Oil For Transformers I-30
I-30 transformer oil can effectively prevent discharge phenomena and power losses under high-voltage electric fields, meeting stringent insulation performance requirements. With lower viscosity and good low-temperature performance, it provides effective cooling and heat transfer, low-temperature start-up performance, and filtration performance. It also exhibits good solubility, capable of dissolving sludge formed during the operation of electrical equipment to avoid damaging insulation materials and affecting heat transfer.
Product Details:Insulating Oil For Transformers I-30
I-30 transformer oil is formulated by blending moderately refined, low pour point, and low sulfur content cycloalkyl base oil with high-quality antioxidant additives, featuring fast heat transfer, good oxidative stability, and excellent electrical performance. The product has stable and reliable performance, produced under strict quality control procedures with fixed product resources.
PARAMETER:
Sports Event | GB2536-11 1-30°C (general purpose) Quality indicators | Typical properties | Test Methods
|
Minimum Cold Commissioning Temperature (LCSET)/°C | -30 | - | - |
Functional characteristics | |||
Pour Point/°C | ≯-40 | -51 | GB/T 3535 |
Kinematic viscosity (40°C)/(mm²/s) | ≯12 | 9.2 | GB/T 265 |
Kinematic viscosity (-30°C)/(mm²/s) | ≯1800 | 1449 | |
Water content/(mg/kg) | ≯30 | 19 | GB/T 7600 |
Breakdown voltage/kV | ≮30 | 66 | GB/T 507 |
Density (20°C)/(kg/m³) | ≯895 | 886.0 | SH/T 0604 |
Dielectric loss factor (90°C) | ≯0.005 | 0.0008 | GB/T 5654 |
Refining/stabilizing properties | |||
exterior condition | clear and transparent | clear and transparent | visual assessment |
Acid value (as KOH)/(mg/g) | ≯0.01 | <0.01 | NB/SH/T 0836 |
Water-soluble acids or bases | not have | not have | GB/T 259 |
Interfacial tension/(mN/m) | ≮40 | 46 | GB/T 6541 |
corrosive sulfur | non-corrosive | non-corrosive | SH/T0804 |
Content of antioxidant (mass fraction)/% | 0.08~0.40 | 0.30 | NB/SH/T0802 |
2-Furfural content/(mg/kg) | ≯0.1 | <0.05 | NB/SH/T0812 |
Operational characteristics | |||
Oxidation stability (120°C) | - | - | NB/SH/T 0811 |
Test time: 500h | - | - | |
--Total acid value (in KOH)/(mg/g) | ≯1.2 | 0.19 | |
--Oil sludge (mass fraction)/% | ≯0.8 | 0.03 | |
--Dielectric loss factor (90°C) | ≯0.500 | 0.051 | GB/T 5654 |
HSE Characteristics | |||
Flash point (closed)/°C | ≮135 | 142 | GB/T 261 |
PCA content (mass fraction)/% | ≯3 | <3 | NB/SH/T 0838 |
Polyoxybiphenyl (PCB) content/(mg/kg) | undetectable | not detected | SH/T 0803 |
1. Classification: Transformer oil
2. Executive Standard: GB 2536-2011 I-30 ℃ (general).
3. Application Scope: I-30 transformer oil is suitable for I-30 transformer oil is suitable for transformers with a voltage rating of 220kV and below, as well as electrical equipment with similar requirements, and can be used in environments above - 30°C.
4. Usage Requirements:
(1) The service life of insulation oil is generally 5-10 years and requires regular replacement.
(2) The replacement of insulation oil must be carried out in accordance with the requirements of the transformer manufacturer, including oil discharge, cleaning, and filling.
Own Factory
Employees at Working
Canned Oil Products
Transportation
SERVICE
Service
Quick: Refers to "quick action", which has two meanings: one is physical speed, that is, try to work as fast as possible and not make customers wait long; The second is the speed of the demonstration. The sincere actions and considerate heart of the employees can arouse customer satisfaction, making them not feel that the waiting time is too long. They can express vitality with quick actions, and not letting customers wait is an important measure of service quality.
Customer Relationship
Flexibility: Receive customers in a clean and efficient manner, and gain customer trust with a flexible and clever work attitude.
FAQ:
Q:What is the company's forecast for the market?
A:We predict that the market will exhibit the following trends:The demand for green and environmentally friendly products from consumers will gradually increase.With the continuous development of technology, products with high technological content will become the mainstream in the market.
Q:What is the company's development plan for the next five years?
A:Product innovation: Increase R&D investment and launch more competitive new products.
Market expansion: Further explore domestic and international markets, improve brand awareness and market share.
Social responsibility: Actively participate in public welfare undertakings, give back to society, and establish a good corporate image.
Q:What is the current ranking and position of the company in the industry?
A:At present, we are in the top 10 or market leadership position in the industry. We have won widespread recognition from customers with our high-quality products and services.