Superior High - Performance Transformer Oil
For electrical equipment, transformer oil serves as a crucial insulating medium, mostly extracted and refined from petroleum, with alkanes and cycloalkanes as its main components. Its excellent electrical insulation can effectively insulate the high-voltage components within the transformer, thus avoiding leakage and short circuits. Due to its good thermal conductivity, it can rapidly transmit the heat generated during the transformer's operation, preventing overheating and damage. Furthermore, it has a certain ability to extinguish arcs, quickly putting out the arc when the switching appliance interrupts the current to produce an arc.
Product Details:Superior High - Performance Transformer Oil
In the context of the power grid, the transformer is an indispensable device. The normal operation of the transformer is crucial for the safety of the power grid, and the transformer oil is directly relevant to the reliability of the transformer's operation. So, we must execute the tasks of choosing, using, and overseeing transformer oil effectively to ensure the secure operation of the transformer. Regarding the principles of selection, first, the performance of the oil should be examined. Its quality must comply with the demands brought about by factors like the voltage level of the equipment and the ambient temperature of the area. Furthermore, the compatibility of the oil with other related insulating materials should be considered.
Parameter:
Sports Event | IEC60296:2020 TVAI (LCSET-40℃) Quality indicators | Typical properties | Test Methods |
Functional characteristics | |||
Pour Point/°C | ≯-50 | -63 | ISO 3016 |
Kinematic viscosity (40°C)/(mm²/s) | ≯12 | 7.0 | ISO 3104 |
Kinematic viscosity (-40°C)/(mm²/s) | ≯2500 | 1736 | IEC 61868 |
Water content/(mg/kg) | ≮30 | 68 | IEC 60814 |
Breakdown voltage/kV | - | IEC 60156 | |
--Untreated oil | ≮30 | 40-70 | |
--Treated oil | ≮70 | >70 | |
Density (20°C)/(kg/m³) | ≯895 | 865 | ISO 12185 |
Dielectric loss factor (90°C) | ≯0.005 | 0.0005 | IEC 60247 |
Refining/stabilizing properties | |||
saturation (color theory) | <0.5 | <0.5 | ISO 2049 |
exterior condition | clear and transparent | Clear and transparent, no precipitation | visual assessment |
Acid value/(mgKOH/g) | ≯0.01 | <0.01 | IEC 62021 |
Interfacial tension/(mN/m) | ≮43 | 47 | IEC 62961 |
Total sulfur content/% | ≯0.05 | 0.003 | ISO 14596 |
corrosive sulfur | non-corrosive | non-corrosive | DIN 51353 |
Potentially corrosive sulfur | non-corrosive | non-corrosive | IEC62535 |
DBDS/(mg/kg) | Not detectable (<5) | undetectable | IEC 62697-1 |
Antioxidant content/% | 0.08~0.4 | 0.37 | IEC 60666 |
Metal passivator/(mg/kg) | Not detectable (<5) | undetectable | IEC 60666 |
2-Furfural content and related substances (single component) (mg/kg) | Not detectable (<0.05) | undetectable | IEC 61198 |
Gas production characteristics (under thermal oxidation)/uI/L) | Hydrogen ≯ 50 | 9 | Appendix A4 Methodology (air-saturated, containing copper) |
Methane ≯ 50 | 1 | ||
Ethane ≯ 50 | 0.2 | ||
Operational characteristics | |||
Chlorine stability (500h) | - | - | IEC 61125 |
--Total acid value (mg (KOH)/g) | ≯0.3 | 0.02 | |
-- Oil sludge/% | ≯0.05 | <0.01 | |
--Dielectric loss factor (90°C) | ≯0.050 | 0.025 | IEC 60247 |
HSE Characteristics | |||
Flash point (closed)/°C | ≮135 | 145 | ISO 2719 |
PCA content/% | <3 | 1.2 | IP 346 |
Polyoxybiphenyl (PCB) content/(mg/kg) | Not detectable (<2) | undetectable | IEC 61619 |
1. Environmental Friendliness of Transformer Oil
Environmental monitoring: Consistent monitoring of the environment and regular maintenance of transformers and other electrical equipment can significantly lower the chances of leaks.
Utilizing an oil spill monitoring system enables quick identification of issues, allowing for prompt corrective actions.
Spill contingency measures: It is crucial to create and implement a robust spill contingency plan to facilitate a swift response in case of a spill, minimizing environmental impact. Additionally, training employees in emergency response procedures ensures they can react effectively during emergencies.
2. Factors Affecting Service Life
Ensuring the service life of transformer oil requires regular quality analysis and testing. The detection process involves checking insulation resistance, absorption ratio, polarization index, dielectric loss, winding leakage current, and microwater levels in the oil. By analyzing these factors, one can ascertain whether the oil has absorbed moisture, contains impurities, or shows signs of aging. If problems are identified, an initial approach may be to regenerate the oil through filtration. However, if this method is impractical or the oil quality is severely degraded, a replacement with new transformer oil should be considered.
Own Factory
Haikun, with 8 15 - square - meter mobile tanks, increases transportation flexibility.
Employees at Working
Haikun's foreign trade employees are proficient in industrial oil shipping documentation. Their professionalism ensures smooth exports.
Canned Oil Products
With efficient packing methods, Haikun Petrochemical packs transformer - related items in 200L iron drums and 20000L liquid bags for smooth international sea - freight logistics.
Transportation
Haikun Petrochemical Technology Co., Ltd. has a mature sea - freight network. We ship transformer - related products to various countries, including those in South America and Africa.
Enterprise Culture
Teamwork is extremely precious in our business. We inspire our employees to form close - knit collaborative relationships, back each other up, draw lessons from one another, take on challenges together, and reach a win - win situation.
Customer Testimonials
Insulating oil from this company is really good. They respect customers and offer high - quality products. The parameters are correct, and the assay sheets are professional. The buying process was easy. - South America, Martinez Luis