Naphthenic Transformer Oil For Transformers T-10
      
                Provide insulation and cooling.In transformers, transformer oil not only provides insulation to prevent the spread of current from one component to another, but also helps to cool the transformer through heat transfer.
Product Details:Naphthenic Transformer Oil For Transformers T-10
Excellent electrical insulation performance, effectively preventing discharge phenomena under electric fields.
Good oxidation stability, effectively preventing the production of acidic substances and sludge.
Good thermal conductivity ensures effective cooling of the transformer core and coils.
PARAMETER:
| Sports Event | Quality Indicators | measured value | Test Methods | 
| Functional characteristics | |||
| Pour Point/°C | -20 | -36.8 | ISO 3016 | 
| Kinematic viscosity(40℃)/(m㎡/s) | ≯12 | 9.13 
 | ISO 3104 | 
| Kinematic viscosity(-10°C)/(mm²/s) | ≯1800 | 1089 | ISO 3104 | 
| Water content/(mg/kg) | ≯30/40 | 6.3 | IEC 60814 | 
| Breakdown voltage/kV(untreated oil) | ≮30 | 62.4 | IEC 60156 | 
| Density(20°C)/(g/ml) | ≯895 | 886 | ISO 12185 | 
| Dielectric loss factor(90°C) | ≯0.005 | 0.00041 | IEC 60247 | 
| Refining/stabilizing properties | |||
| exterior condition | Clear and transparent,free of sediment and suspension(of atmospheric pollution) | Clear and transparent,free of sediment and suspension(of atmospheric pollution) | visual assessment | 
| Acid value(mgKOH/g) | ≯0.01 | 0.0008 | IEC 62021- 1 | 
| Interfacial tension/(mN/m) | No general requirements | 46 | ISO 6295 | 
| Total sulfur content(mass fraction)/% | No general requirements | No general requirements | ISO 14596 | 
| corrosive sulfur | non-corrosive | non-corrosive | DIN 51353 | 
| Content of antioxidant additives(mass fraction)/percent Oil with antioxidant additives(U) | ≯0.08 | 0.059 | IEC 60666 | 
| 2-Furfural content/(mg/kg) | ≯0.1 | 0.012 | IEC 61198 | 
| Operational characteristics | |||
| Oxidation stability(120°C) Test time:332h | - | - | - | 
| --Total acid value(in KOH)/(mg/g) | ≯1.2 | 0.04 | IEC 61125 Act C | 
| --Oil sludge(mass fraction)/% | ≯0.8 | 0.020 | IEC 61125 Act C | 
| --Dielectric loss factor(90°C) | ≯0.500 | 0.004 | IEC 60247 | 
| Gassing/(mm/min) | No general requirements | No general requirements | IEC 60628 | 
| Health Safety and Environmental Characteristics(HSE) | |||
| Flash point(closed)/°C | ≮135 | 147.3 | ISO 2719 | 
| PCA content(mass fraction)/% | ≯3 | 0.8 | BS 2000 Part 346 | 
| Polychlorinated biphenyl(PCB)content/(mass fraction)(mg/kg) | undetectable | undetectable | IEC 61619 | 
1. Classification: Transformer oil
2. Executive Standard: GB 2536-2011 T-10 ℃ (general).
3. Application Scope: T-10 transformer oil is suitable for transformers with antioxidant content not exceeding 0.08% as required by users, as well as electrical equipment with similar requirements.
4. Performance requirements for transformer insulation oil:
(1) Flash point and self ignition point: Flash point refers to the lowest temperature at which insulating oil can burn under certain conditions, while self ignition point refers to the lowest temperature at which insulating oil can self burn under certain conditions. The higher the flash point and self ignition point, the higher the safety of the insulating oil.
(2) Antioxidant performance: Antioxidant performance refers to the ability of insulating oil to maintain stability under the action of high temperature and oxygen. The better the antioxidant performance, the longer the lifespan of the insulating oil.
Own Factory
Employees at Working
Canned Oil Products
Transportation
SERVICE
Service philosophy
Respect customers, products and services should be based on customer needs, and provide customers with better value choices for products and services.
To understand customers, one should research, design, and improve services from their perspective.
Power transmission and transformation services
We have built a complete industrial chain in the field of power transmission and transformation, including transformers, converter valves, switches, secondary equipment, cables, and casings.We provide turnkey engineering and system solutions for more than 30 countries, including survey, design, construction, installation, commissioning, training, operation, and maintenance.
FAQ:
1. What are the advantages of your company ?
We have many professionals, technical personnel, more competitive prices and best after-dales service.
2.How can we ensure the quality of transformer oil?
Our transformer oil will first undergo testing with a tester. It has a low pour point, excellent electrical insulation performance, excellent thermal stability and oxidation stability, and effectively prevents oil aging. Service is attentive, after-sales service is reassuring, please rest assured to purchase.


 
                                            
                                                                                        
                                         
                                            
                                                                                        
                                         
                                            
                                                                                        
                                        




 
                   
                  